www.bimba.com Technical Assistance: 800-44-BIMBA 22
SPECIFICATIONS
Description Specification
Zero Adjustment
50% of Total Full Scale Output between
both adjustments
Span Adjustment
DECEL Adjustment Approximately 0.5 to 13.5 volts
Deadband Adjustment Approximately 0.005 to 0.500 Volts
@ Position Discrete signal that Sinks to Ground when
Within Deadband zone. 20mA Maximum.
Current Position 0 to 10 VDC signal, 1M ohm input
impedence required for input device.
Operation at Power Loss All valves close at power loss.
Input Supply Voltage 23.5 to 24.5 VDC, 1 amp
Operating Pressure 70 to 80 psig
Air Requirement Regulated and Filtered to 5 micron
Operational Temperature Range 0 to 100 degrees F (Electronics\PC Board)
Reverse Polarity Protected
Overvoltage Protected
APPLICATION SIZING and “RULES OF THUMB
PFC Cylinder/PCS Valve System Matching and Sizing Recommendations*
Bore Size
PCS
Model
Stroke
Range
Maximu
m
Payload
Average
Velocity
Maximum
External
Friction
Zero
Friction
Deadband
**
½ Maximum
Friction
Deadband
Maximum
Friction
Deadbead
Minimum
Step
PFC-09 (1-1/16")
PCS-1
2" to 7"
1 lb 2.75 in/sec zero +/- 50mV NA NA
0.080"
PFC-09 (1 1/16")
PCS-1
8" to 24"
30
pounds
4.00 in/sec 5 pounds +/- 40mV +/- 80mV +/- 160mV
0.20 - 0.39"
PFC-17 (1-1/2")
PCS-1
1" to 3"
2 lbs 2.50 in/sec zero +/- 25mV NA NA
0.040"
PFC-17 (1 1/2")
PCS-2
4" to 24"
50
pounds
5.50 in/sec 10 pounds +/- 20mV +/- 40mV +/- 80mV
2 times
Deadband
PFC-31 (2")
PCS-2
1" to 2"
4 lbs 2.75 in/sec zero +/- 50mV NA NA
0.020"
PFC-31 (2")
PCS-3
3" to 24"
90
pounds
6.50 in/sec 20 pounds +/- 15mV +/- 30mV +/- 60mV
2 times
Deadband
*If your application requires lower velocities or payloads, you may be able to reduce
the minimum recommended deadband setting, or if your deadband requirements can
accommodate a large range, you may be able to increase your payload higher than the
recommended values.
**Note: Use the Formulas in the Glossary to convert the Minimum Deadband shown
in the table to displacement.
Assumptions used for Sizing Values recommended above:
• Values shown above are with no overshoot. If overshoot is acceptable for your
application, the Deadband may possibly be less than specified above. However,
be sure your system cannot go unstable. Refer to Caution statement on page 20.
• PFC cylinder with Option L is used. (Option L has very low friction seals. The
standard PFC utilizes a rod wiper which increases friction significantly, which
will have adverse effects on positioning capabilities).